· SS7 Over IP Monitor
with DAC ·
The IPTubeSS7MonDE1
encapsulates SS7 Call Detail Messages from SS7 Signalling nodes
into IP packets for delivery to an SS7 Protocol analyzer. The IPTubeSS7MonDE1
provides for remote monitoring of SS7 based Telecom Switches systems
via LANs, WANs, MANs, and Wireless Ethernet.
The IPTubeSS7MonDE1's
E1 interface is connected to the E1 monitor interface of the Telecom
Switch and is setup to monitor the SS7 traffic. At the Central Support
Site an IPTubeSS7SIGE1
receives the SS7 Over IP packets and sends the SS7 Messages out
its E1 interface to an SS7 Protocol Analyzer.
The IPTubeSS7MonDE1
has two E1 interfaces that are Digitallly Cross Connected. One E1
connects to the SS7 equipment's E1 link and the other connects to
the E1 line. The SS7 communication channel between each of the SS7
nodes is tapped and the messages from each SS7 Signalling node are
sent to an IPTubeSS7SIGE1
that is connected to the E1 interface an SS7 protocol analyzer.
IPTubeSS7MONDE1
Brochure in PDF Format
Centralized
SS7 protocol Analyzer
The Centralized SS7 protocol Analyzer is utilized for: Surveillance,
Call Detail Records processing, Real-Time Signaling Network Monitor,
Traffic Monitor and Analysis, Alarm management, Fraud Detection,
Billing Verification, Revenue Assurance and Protocol Analysis:
Call Tracing and Decoding.
Industry
Standard SS7 Framer
The IPTubeSS7MonDE11
uses an industry standard SS7 Framer to receive and transmit SS7
messages. Minimal IP bandwidth is required to deliver SS7 since
only the message data is encapsulated into IP packets.
LAN
Network Interface:
· One 10BaseT Ethernet
LAN Network Protocols Supported:
· IP, TCP, UDP, ICMP
E1 Over IP Protocol:
SS7 Over IP - SS7OIP
Quality of Service:
· Configurable IP Type of Service Bits
· IANA Registered UDP Port 3175
E1/Fractional E1 Specifications:
· Framing - CRC4 or FAS or UNFRAMED
· Coding - HDB3 or AMI
· Supports DS0 assignments from 1 to 31
Regulatory:
· Safety -IEC60950 Third Edition
CB
TEST CERTIFICATE
· EMC - EN55022:1994+A1&A2
EN55024,
ICES-003 1997
CISPR
22 Level A
· Telecom - TBR12, TBR13
· CE
|
TFTP
Upgrade Capable (Flash ROMs):
· IPTube is operational during upgrade
Management:
· Telnet support with Edit and Paste
Templates
· Console Port for Out of Band Management
· SNMP support (MIB I, MIB II)
· Remote configuration, monitoring, & reset
Console Port:
·
RJ45 to DB9 Female DCE adapter shipped with product. Enables
direct connection to Com1.
Power:
·
12-36 VDC
·
-48 VDC Optional
Dimensions:
·
9" (L) x 7" (W) x 1.50" (H)
|
Back Panel
Console Port Connector
· RJ 45 to DB 9 Female Adapter provided
|
|
Telco1: E1 Telecom
Circuit Interface RJ48S
|
4 Port 10BaseT Ethernet
Hub |
|
DS1: E1 Connection to
SS7 Signalling Node |
|
Power
12-36 VDC
-48 VDC Optional
|
Engage Communication ·
9565 Soquel Drive, Aptos, CA 95003
Tel: (831) 688-1021 · Fax: (831) 688-1421 · sales@engageinc.com
© Copyright 1989-2005 Engage Communication, Inc. Engage Communication has moved to WWW.ENGAGEINC.COM
|